Customization: | Available |
---|---|
After-sales Service: | Support |
Warranty: | 5 Years (10 Years Optional) |
Still deciding? Get samples of US$ 1300/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model
|
SUN-5K -SG01HP3-EU-AM2
|
SUN-6K -SG01HP3-EU-AM2
|
SUN-8K -SG01HP3-EU-AM2
|
SUN-10K -SG01HP3-EU-AM2
|
SUN-12K -SG01HP3-EU-AM2
|
SUN-15K -SG01HP3-EU-AM2
|
SUN-20K -SG01HP3-EU-AM2
|
SUN-25K -SG01HP3-EU-AM2
|
Battery Input Data
|
|
|||||||
Battery Type
|
Lithium-ion
|
|||||||
Battery Voltage Range(V)
|
160-700
|
|||||||
Max.Charging Current(A)
|
30
|
30
|
37
|
50
|
||||
Max.Discharging Current(A)
|
30
|
30
|
37
|
50
|
||||
Charging Strategy for Li-ion Battery
|
Self-adaption to BMS
|
|||||||
Number of battery input
|
1
|
|||||||
PV String Input Data
|
|
|||||||
Max DC Input Power(W)
|
6500
|
7800
|
10400
|
13000
|
15600
|
19500
|
26000
|
32500
|
Max DC Input Voltage(V)
|
1000
|
|||||||
Start-up Voltage(V)
|
180
|
|||||||
MPPT Voltage Range(V)
|
150-850
|
|||||||
Rated DC Input Voltage(V)
|
600
|
700
|
||||||
Max Input Short-Circuit Current(A)
|
30+30
|
39+30
|
39+39
|
|||||
Max Operating PV Input Current(A)
|
20+20
|
26+20
|
26+26
|
|||||
No.of MPP Trackers/No.of String Per MPP Tracker
|
2/1+1
|
2/2+1
|
2/2+2
|
|||||
AC Input/Output Data
|
|
|||||||
Rated AC Input/Output Active Power(W)
|
5000
|
6000
|
8000
|
10000
|
12000
|
15000
|
20000
|
25000
|
Max AC Input/Output Apparent Power (VA)
|
5500
|
6600
|
8800
|
11000
|
13200
|
16500
|
22000
|
27500
|
Peak Power (off-grid)(W)
|
1.5 times of rated power,10s
|
|||||||
Rated AC Input/Output Current(A)
|
7.6/7.3
|
9.1/8.7
|
12.2/11.6
|
15.2/14.5
|
18.2/17.4
|
22.8/21.8
|
30.4/29
|
37.9/36.3
|
Max AC Input/Output Current(A)
|
8.4/8
|
10/9.6
|
13.4/12.8
|
16.7/16
|
20/19.2
|
25/24
|
33.4/31.9
|
41.7/39.9
|
Max. Three-phase Unbalanced Output Current(A)
|
13
|
13
|
18
|
22
|
25
|
30
|
35
|
41.7
|
Max Continuous AC Passthrough (grid to load)(A)
|
40
|
80
|
||||||
Rated Input/Output Voltage/Range(V)
|
220/380V,230/400V 0.85Un-1.1Un
|
|||||||
Grid Connection Form
|
3L+N+PE
|
|||||||
Rated Input/Output Grid Frequency/Range
|
50Hz/45Hz-55Hz 60Hz/55Hz-65Hz
|
|||||||
Power Factor Adjustment Range
|
0.8 leading-0.8 lagging
|
|||||||
Total Current Harmonic Distortion THDi
|
<3% (of nominal power)
|
|||||||
DC Injection Current
|
<0.5%ln
|
|||||||
Efficiency
|
|
|||||||
Max Efficiency
|
97.6%
|
|||||||
Euro Efficiency
|
97.0%
|
|||||||
MPPT Efficiency
|
>99%
|
|||||||
Equipment Protection
|
|
|||||||
DC Polarity Reverse Connection Protection
|
YES
|
|||||||
AC Output Overcurrent Protection
|
YES
|
|||||||
AC Output Overvoltage Protection
|
YES
|
|||||||
AC Output Short Circuit Protection
|
YES
|
|||||||
Thermal Protection
|
YES
|
|||||||
DC Terminal Insulation Impedance Monitoring
|
YES
|
|||||||
DC Component Monitoring
|
YES
|
|||||||
Ground Fault Current Monitoring
|
YES
|
|||||||
Power Network Monitoring
|
YES
|
|||||||
Island Protection Monitoring
|
YES
|
|||||||
Earth Fault Detection
|
YES
|
|||||||
DC Input Switch
|
YES
|
|||||||
Overvoltage Load Drop Protection
|
YES
|
|||||||
Residual Current (RCD) Detection
|
YES
|
|||||||
Surge Protection Level
|
TYPE II(DC),TYPE II(AC)
|
|||||||
Interface
|
|
|||||||
Communication Interface
|
WIFI,RS485,CAN
|
|||||||
General Data
|
|
|||||||
Operating Temperature Range
|
-40 to +60ºC, >45ºC Derating
|
|||||||
Permissible Ambient Humidity
|
0-100%
|
|||||||
Permissible Altitude
|
2000m
|
|||||||
Noise
|
≤ 55 dB(A)
|
|||||||
Ingress Protection(IP) Rating
|
IP 65
|
|||||||
Inverter Topology
|
Non-Isolated
|
|||||||
Over Voltage Category
|
OVC II(DC),OVC III(AC)
|
|||||||
Cabinet size(W*H*D)[mm]
|
408*638*237(Excluding connectors and brackets)
|
|||||||
Weight[kg]
|
30.5
|
|||||||
Warranty
|
5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy
|
|||||||
Type Of Cooling
|
natural cooling
|
Intelligent air cooling
|
||||||
Grid Regulation
|
IEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105
|
|||||||
Safety EMC/Standard
|
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
|